Compressor enclosure is a bespoke housing built from sandwich acoustic panels around piston, screw or turbo compressors. With a steel outer skin, mineral-wool absorber layer and barrier membrane where required, it delivers 15-30 dB ambient-noise reduction. Designed together with a service door, observation window, inlet/outlet silencers and vibration mounts.
What is a compressor enclosure?
A compressor enclosure is an acoustic housing built around a noisy compressor. Manufactured to site-specific measurements or from factory-standard modules. The inner face is absorbent; the outer face is steel or stainless. Cooling airflow and service access are central to the design.
Sandwich panel build-up
- Outer skin: 1-2 mm galvanised / stainless / painted steel
- Barrier layer (when needed): EPDM membrane 4-8 kg/m²
- Absorber layer: mineral wool 80-120 kg/m³, 50-100 mm
- Inner face: perforated steel — sound wave passes through
- Total thickness: 50 / 75 / 100 / 150 mm
Components
- Sandwich acoustic panel (Rw 30-40 dB)
- Service door (acoustic gasket + drop-down threshold)
- Acoustic observation window (laminated double glass)
- Inlet / outlet silencer (mandatory)
- Vibration mounts / spring isolators (base)
- Interior lighting + service socket
Performance
- Insertion loss: 15-30 dB (by compressor type)
- Operating temperature: -20 °C / +90 °C inside
- Cooling air: provided through silencer + fan
- IP protection: IP54 (interior), IP65 (exterior)
- Fire class: A1 (mineral wool), A2 (sandwich)
By compressor type
- Piston: low frequency + vibration → combined spring+mount
- Screw: broadband noise → high absorption
- Turbo: high frequency → thin absorber and detail
- Vacuum: negative pressure + intake silencer
Where it is used
- Industrial air-compressor plants
- Cooling systems (chillers / splits)
- Oil, gas and energy process facilities
- White-goods, food and pharma production
- Boiler and natural-gas distribution stations
- Maritime and ship equipment
Engineering process
1) On-site measurement (LpA, octave bands). 2) Target IL determined. 3) Cooling load and silencer duct size calculated. 4) Service-access plan. 5) Sandwich-panel class selected. 6) Manufacture, installation and verification measurement.
Related
For general enclosure design see industrial acoustic enclosure; for silencers see silencer manufacturing.
Features
Internationally fire-retardant certified (BS476 Class 0, UNI 9175 M1)
Custom-size and custom-color production options
High acoustic performance and long service life
Easy installation and application-friendly
Durability in industrial and residential projects
Usage Process
Site Measurement
On-site acoustic and dimensional measurement.
Product Selection
The right specification for the performance target.
Cutting & Supply
Custom-size preparation and packaging.
Installation
DIY application or expert installation.
Technical Specifications
| Standard | BS476 Class 0, UNI 9175 M1 |
|---|---|
| Typical Thickness | 20-100 mm (project-dependent) |
| Custom Cutting | Available (2-5 business days) |